
{"id":4541,"date":"2024-04-29T14:27:00","date_gmt":"2024-04-29T18:27:00","guid":{"rendered":"https:\/\/spraysensors-cn.tecnar.com\/?p=4541"},"modified":"2024-12-23T12:48:24","modified_gmt":"2024-12-23T17:48:24","slug":"understanding-the-impact-of-binary-plasma-gas-mixtures-in-plasma-spraying","status":"publish","type":"post","link":"https:\/\/spraysensors-cn.tecnar.com\/en\/understanding-the-impact-of-binary-plasma-gas-mixtures-in-plasma-spraying\/","title":{"rendered":"Understanding the Impact of Binary Plasma Gas Mixtures in Plasma Spraying"},"content":{"rendered":"<p>In plasma spraying, H2 or N2 is commonly added to the primary Ar plasma which may increase the specific enthalpy, thermal conductivity and thus improve the process efficiency. The objective of this study is to provide a process characterization of a three-cathode plasma torch with various binary gas compositions. Several process diagnostics are used to characterize the impact of binary plasma gas mixtures in plasma spraying. High-speed video analysis is utilized to capture the jet fluctuations of the studied process parameters. In addition, current and voltage measurements are performed to further complement the plasma diagnostics. The impact of the binary plasma gas mixtures is determined using particle diagnostic system DPV-2000 by measuring the particle in-flight properties of Al2O3 feedstock. Furthermore, the deposition efficiency (DE) of the investigated process parameters is determined. The results show that at the identical volumetric flow rate and current, the addition of H2 yields the highest particle temperatures, followed by Ar\/N2 mixtures and pure Ar plasma. In reverse order, pure Ar plasma results in the highest particle velocities. In addition, the increased DE of plasma spraying with binary gas mixtures for Al2O3 coatings offers the potential to increase the deposition rate of other ceramic materials. This study provides a comprehensive correlation between plasma and particle diagnostics and the deposition efficiency of binary plasma gas mixtures.<\/p>\n<p><a class=\"btn-tec black\" href=\"https:\/\/dl.asminternational.org\/itsc\/proceedings-pdf\/ITSC2024\/84864\/689\/692734\/itsc2024p0689.pdf\" target=\"_blank\" rel=\"noopener\">Link to publication<\/a><\/p>\n<p>Key words: alumina, deposition efficiency, gas compositions, particle in-flight properties, plasma spraying, plasma torches<\/p>\n<p><em><small>Originally published as ITSC2024 Thermal Spray Proceedings online paper (Paper No: itsc2024p0689, pp. 689-695; 7 pages)<br \/>\nBy K. Bobzin, H. Heinemann, M. Erck, K. Jasutyn<\/small><\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>In plasma spraying, H2 or N2 is commonly added to the primary Ar plasma which may increase the specific enthalpy, [&#8230;]<\/p>\n<p><a class=\"btn btn-secondary understrap-read-more-link\" href=\"https:\/\/spraysensors-cn.tecnar.com\/en\/understanding-the-impact-of-binary-plasma-gas-mixtures-in-plasma-spraying\/\">Read More&#8230;<\/a><\/p>\n","protected":false},"author":20,"featured_media":4542,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[42],"tags":[],"class_list":["post-4541","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-dpv-evolution-2"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Understanding the Impact of Binary Plasma Gas Mixtures in Plasma Spraying - Tecnar Thermal Spray<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/spraysensors-cn.tecnar.com\/understanding-the-impact-of-binary-plasma-gas-mixtures-in-plasma-spraying\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Understanding the Impact of Binary Plasma Gas Mixtures in Plasma Spraying - Tecnar Thermal Spray\" \/>\n<meta property=\"og:description\" content=\"In plasma spraying, H2 or N2 is commonly added to the primary Ar plasma which may increase the specific enthalpy, [...]Read More...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/spraysensors-cn.tecnar.com\/understanding-the-impact-of-binary-plasma-gas-mixtures-in-plasma-spraying\/\" \/>\n<meta property=\"og:site_name\" content=\"Tecnar Thermal Spray\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/tecnarautomation\" \/>\n<meta property=\"article:published_time\" content=\"2024-04-29T18:27:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-12-23T17:48:24+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/spraysensors-cn.tecnar.com\/wp-content\/uploads\/2024\/11\/Web-image-39.png\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Flavia FU\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Flavia FU\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/spraysensors-cn.tecnar.com\/understanding-the-impact-of-binary-plasma-gas-mixtures-in-plasma-spraying\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/spraysensors-cn.tecnar.com\/understanding-the-impact-of-binary-plasma-gas-mixtures-in-plasma-spraying\/\"},\"author\":{\"name\":\"Flavia FU\",\"@id\":\"https:\/\/spraysensors-cn.tecnar.com\/#\/schema\/person\/3162fa7791842106828b1897ffb40076\"},\"headline\":\"Understanding the Impact of Binary Plasma Gas Mixtures in Plasma Spraying\",\"datePublished\":\"2024-04-29T18:27:00+00:00\",\"dateModified\":\"2024-12-23T17:48:24+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/spraysensors-cn.tecnar.com\/understanding-the-impact-of-binary-plasma-gas-mixtures-in-plasma-spraying\/\"},\"wordCount\":275,\"publisher\":{\"@id\":\"https:\/\/spraysensors-cn.tecnar.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/spraysensors-cn.tecnar.com\/understanding-the-impact-of-binary-plasma-gas-mixtures-in-plasma-spraying\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/spraysensors-cn.tecnar.com\/wp-content\/uploads\/2024\/11\/Web-image-39.png\",\"articleSection\":[\"DPV\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/spraysensors-cn.tecnar.com\/understanding-the-impact-of-binary-plasma-gas-mixtures-in-plasma-spraying\/\",\"url\":\"https:\/\/spraysensors-cn.tecnar.com\/understanding-the-impact-of-binary-plasma-gas-mixtures-in-plasma-spraying\/\",\"name\":\"Understanding the Impact of Binary Plasma Gas Mixtures in Plasma Spraying - Tecnar Thermal Spray\",\"isPartOf\":{\"@id\":\"https:\/\/spraysensors-cn.tecnar.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/spraysensors-cn.tecnar.com\/understanding-the-impact-of-binary-plasma-gas-mixtures-in-plasma-spraying\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/spraysensors-cn.tecnar.com\/understanding-the-impact-of-binary-plasma-gas-mixtures-in-plasma-spraying\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/spraysensors-cn.tecnar.com\/wp-content\/uploads\/2024\/11\/Web-image-39.png\",\"datePublished\":\"2024-04-29T18:27:00+00:00\",\"dateModified\":\"2024-12-23T17:48:24+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/spraysensors-cn.tecnar.com\/understanding-the-impact-of-binary-plasma-gas-mixtures-in-plasma-spraying\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/spraysensors-cn.tecnar.com\/understanding-the-impact-of-binary-plasma-gas-mixtures-in-plasma-spraying\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/spraysensors-cn.tecnar.com\/understanding-the-impact-of-binary-plasma-gas-mixtures-in-plasma-spraying\/#primaryimage\",\"url\":\"https:\/\/spraysensors-cn.tecnar.com\/wp-content\/uploads\/2024\/11\/Web-image-39.png\",\"contentUrl\":\"https:\/\/spraysensors-cn.tecnar.com\/wp-content\/uploads\/2024\/11\/Web-image-39.png\",\"width\":800,\"height\":500},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/spraysensors-cn.tecnar.com\/understanding-the-impact-of-binary-plasma-gas-mixtures-in-plasma-spraying\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/spraysensors-cn.tecnar.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Understanding the Impact of Binary Plasma Gas Mixtures in Plasma Spraying\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/spraysensors-cn.tecnar.com\/#website\",\"url\":\"https:\/\/spraysensors-cn.tecnar.com\/\",\"name\":\"Lut by Tecnar\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/spraysensors-cn.tecnar.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/spraysensors-cn.tecnar.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/spraysensors-cn.tecnar.com\/#organization\",\"name\":\"Tecnar Automation Ltd\",\"url\":\"https:\/\/spraysensors-cn.tecnar.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/spraysensors-cn.tecnar.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/spraysensors-cn.tecnar.com\/wp-content\/uploads\/2021\/05\/cropped-Logo_web_480x215-2.png\",\"contentUrl\":\"https:\/\/spraysensors-cn.tecnar.com\/wp-content\/uploads\/2021\/05\/cropped-Logo_web_480x215-2.png\",\"width\":480,\"height\":186,\"caption\":\"Tecnar Automation Ltd\"},\"image\":{\"@id\":\"https:\/\/spraysensors-cn.tecnar.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/tecnarautomation\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/spraysensors-cn.tecnar.com\/#\/schema\/person\/3162fa7791842106828b1897ffb40076\",\"name\":\"Flavia FU\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/spraysensors-cn.tecnar.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/8c690964c5cbfc527e3619c2837fb8cf?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/8c690964c5cbfc527e3619c2837fb8cf?s=96&d=mm&r=g\",\"caption\":\"Flavia FU\"},\"url\":\"https:\/\/spraysensors-cn.tecnar.com\/en\/author\/flavia\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Understanding the Impact of Binary Plasma Gas Mixtures in Plasma Spraying - Tecnar Thermal Spray","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/spraysensors-cn.tecnar.com\/understanding-the-impact-of-binary-plasma-gas-mixtures-in-plasma-spraying\/","og_locale":"en_US","og_type":"article","og_title":"Understanding the Impact of Binary Plasma Gas Mixtures in Plasma Spraying - Tecnar Thermal Spray","og_description":"In plasma spraying, H2 or N2 is commonly added to the primary Ar plasma which may increase the specific enthalpy, [...]Read More...","og_url":"https:\/\/spraysensors-cn.tecnar.com\/understanding-the-impact-of-binary-plasma-gas-mixtures-in-plasma-spraying\/","og_site_name":"Tecnar Thermal Spray","article_publisher":"https:\/\/www.facebook.com\/tecnarautomation","article_published_time":"2024-04-29T18:27:00+00:00","article_modified_time":"2024-12-23T17:48:24+00:00","og_image":[{"width":800,"height":500,"url":"https:\/\/spraysensors-cn.tecnar.com\/wp-content\/uploads\/2024\/11\/Web-image-39.png","type":"image\/png"}],"author":"Flavia FU","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Flavia FU","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/spraysensors-cn.tecnar.com\/understanding-the-impact-of-binary-plasma-gas-mixtures-in-plasma-spraying\/#article","isPartOf":{"@id":"https:\/\/spraysensors-cn.tecnar.com\/understanding-the-impact-of-binary-plasma-gas-mixtures-in-plasma-spraying\/"},"author":{"name":"Flavia FU","@id":"https:\/\/spraysensors-cn.tecnar.com\/#\/schema\/person\/3162fa7791842106828b1897ffb40076"},"headline":"Understanding the Impact of Binary Plasma Gas Mixtures in Plasma Spraying","datePublished":"2024-04-29T18:27:00+00:00","dateModified":"2024-12-23T17:48:24+00:00","mainEntityOfPage":{"@id":"https:\/\/spraysensors-cn.tecnar.com\/understanding-the-impact-of-binary-plasma-gas-mixtures-in-plasma-spraying\/"},"wordCount":275,"publisher":{"@id":"https:\/\/spraysensors-cn.tecnar.com\/#organization"},"image":{"@id":"https:\/\/spraysensors-cn.tecnar.com\/understanding-the-impact-of-binary-plasma-gas-mixtures-in-plasma-spraying\/#primaryimage"},"thumbnailUrl":"https:\/\/spraysensors-cn.tecnar.com\/wp-content\/uploads\/2024\/11\/Web-image-39.png","articleSection":["DPV"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/spraysensors-cn.tecnar.com\/understanding-the-impact-of-binary-plasma-gas-mixtures-in-plasma-spraying\/","url":"https:\/\/spraysensors-cn.tecnar.com\/understanding-the-impact-of-binary-plasma-gas-mixtures-in-plasma-spraying\/","name":"Understanding the Impact of Binary Plasma Gas Mixtures in Plasma Spraying - Tecnar Thermal Spray","isPartOf":{"@id":"https:\/\/spraysensors-cn.tecnar.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/spraysensors-cn.tecnar.com\/understanding-the-impact-of-binary-plasma-gas-mixtures-in-plasma-spraying\/#primaryimage"},"image":{"@id":"https:\/\/spraysensors-cn.tecnar.com\/understanding-the-impact-of-binary-plasma-gas-mixtures-in-plasma-spraying\/#primaryimage"},"thumbnailUrl":"https:\/\/spraysensors-cn.tecnar.com\/wp-content\/uploads\/2024\/11\/Web-image-39.png","datePublished":"2024-04-29T18:27:00+00:00","dateModified":"2024-12-23T17:48:24+00:00","breadcrumb":{"@id":"https:\/\/spraysensors-cn.tecnar.com\/understanding-the-impact-of-binary-plasma-gas-mixtures-in-plasma-spraying\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/spraysensors-cn.tecnar.com\/understanding-the-impact-of-binary-plasma-gas-mixtures-in-plasma-spraying\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/spraysensors-cn.tecnar.com\/understanding-the-impact-of-binary-plasma-gas-mixtures-in-plasma-spraying\/#primaryimage","url":"https:\/\/spraysensors-cn.tecnar.com\/wp-content\/uploads\/2024\/11\/Web-image-39.png","contentUrl":"https:\/\/spraysensors-cn.tecnar.com\/wp-content\/uploads\/2024\/11\/Web-image-39.png","width":800,"height":500},{"@type":"BreadcrumbList","@id":"https:\/\/spraysensors-cn.tecnar.com\/understanding-the-impact-of-binary-plasma-gas-mixtures-in-plasma-spraying\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/spraysensors-cn.tecnar.com\/"},{"@type":"ListItem","position":2,"name":"Understanding the Impact of Binary Plasma Gas Mixtures in Plasma Spraying"}]},{"@type":"WebSite","@id":"https:\/\/spraysensors-cn.tecnar.com\/#website","url":"https:\/\/spraysensors-cn.tecnar.com\/","name":"Lut by Tecnar","description":"","publisher":{"@id":"https:\/\/spraysensors-cn.tecnar.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/spraysensors-cn.tecnar.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/spraysensors-cn.tecnar.com\/#organization","name":"Tecnar Automation Ltd","url":"https:\/\/spraysensors-cn.tecnar.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/spraysensors-cn.tecnar.com\/#\/schema\/logo\/image\/","url":"https:\/\/spraysensors-cn.tecnar.com\/wp-content\/uploads\/2021\/05\/cropped-Logo_web_480x215-2.png","contentUrl":"https:\/\/spraysensors-cn.tecnar.com\/wp-content\/uploads\/2021\/05\/cropped-Logo_web_480x215-2.png","width":480,"height":186,"caption":"Tecnar Automation Ltd"},"image":{"@id":"https:\/\/spraysensors-cn.tecnar.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/tecnarautomation"]},{"@type":"Person","@id":"https:\/\/spraysensors-cn.tecnar.com\/#\/schema\/person\/3162fa7791842106828b1897ffb40076","name":"Flavia FU","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/spraysensors-cn.tecnar.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/8c690964c5cbfc527e3619c2837fb8cf?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8c690964c5cbfc527e3619c2837fb8cf?s=96&d=mm&r=g","caption":"Flavia FU"},"url":"https:\/\/spraysensors-cn.tecnar.com\/en\/author\/flavia\/"}]}},"_links":{"self":[{"href":"https:\/\/spraysensors-cn.tecnar.com\/en\/wp-json\/wp\/v2\/posts\/4541","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/spraysensors-cn.tecnar.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/spraysensors-cn.tecnar.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/spraysensors-cn.tecnar.com\/en\/wp-json\/wp\/v2\/users\/20"}],"replies":[{"embeddable":true,"href":"https:\/\/spraysensors-cn.tecnar.com\/en\/wp-json\/wp\/v2\/comments?post=4541"}],"version-history":[{"count":3,"href":"https:\/\/spraysensors-cn.tecnar.com\/en\/wp-json\/wp\/v2\/posts\/4541\/revisions"}],"predecessor-version":[{"id":4668,"href":"https:\/\/spraysensors-cn.tecnar.com\/en\/wp-json\/wp\/v2\/posts\/4541\/revisions\/4668"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/spraysensors-cn.tecnar.com\/en\/wp-json\/wp\/v2\/media\/4542"}],"wp:attachment":[{"href":"https:\/\/spraysensors-cn.tecnar.com\/en\/wp-json\/wp\/v2\/media?parent=4541"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/spraysensors-cn.tecnar.com\/en\/wp-json\/wp\/v2\/categories?post=4541"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/spraysensors-cn.tecnar.com\/en\/wp-json\/wp\/v2\/tags?post=4541"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}